Pressure Reducing Valve
HOME > PRODUCTS
OUR PRODUCT
Pressure Reducing Valve
PRODUCT CATEGORIES
- All
- +- Actuators
- +- Automatic Strainer
- +- Backpressure Valve
- +- Basket Strainer
- +- Check Valve
- +- Condensate Return System
- +- Electric Steam Generator
- +- Emergency Shower Systems
- +- Eye Wash Station
- +- Flowmeter
- +- Gas Taps
- +- Hot Water System
- +- Laboratory Fittings
- +- Manual Valve
- +- Overflow Valve
- +- Pressure Reducing Valve
- +- Pressure Safety Valve
- +- Pump
- +- Pumping Trap
- +- Safety Relief Valve
- +- Safety Shower
- +- Safety Valve
- +- Sampling Valves
- +- Sight Glass
- +- Steam Boiler
- +- Steam Generator
- +- Steam Separator
- +- Steam Trap
- +- Steam Trap Survey Equipment
- +- Strainer
- +- Temperature Control Valve
- +- Water Taps
- +- Y-Strainer
BRANDS
- 317
- Apollo
- Archron
- Broen
- Broen-Lab
- Burkert
- CERTUSS
- Clorius Controls – Marine Valves
- Comanche
- Conflow
- Controlli
- Demo
- Fabricated Strainer
- Ferrenti
- Goetze Armaturen Relief Valves & Reducing Valves
- Industrial Mixing Valves
- ITT Mcdonnell & Miller
- Max Müller
- Miyawaki Steam Product
- Pyrex
- Rampini-valves
- Shin Woo
- SU2N
- TekFlow Flowmeter
A pressure reducing valve reduces the input pressure of a fluid or gas to a lower, stable output pressure. The main purpose of a pressure reducing valve is to ensure that the downstream system operates within safe and efficient pressure limits, regardless of fluctuations in the upstream pressure.
Frequently Asked Questions
What does a pressure reducing valve do, and why reduce steam pressure?
A pressure reducing valve takes a variable, higher inlet pressure and holds a steady, lower outlet pressure regardless of changes upstream or in demand downstream.
Steam is usually generated and distributed at high pressure because it carries more energy per unit volume, which means smaller mains. But most equipment wants steam at a lower, tightly controlled pressure: lower pressure steam has a higher latent heat content, gives better temperature control, and keeps equipment within its design rating. Reducing at the point of use gets both benefits.
Direct-acting or pilot-operated — which type do I need?
A direct-acting valve is simpler, compact and cheaper, but has a wider proportional band, meaning outlet pressure drifts more as flow changes. It suits small, steady loads where precise control is not critical.
A pilot-operated valve uses the pressure differential to drive the main valve, giving much tighter outlet control across a wide range of flows, and greater capacity for the same size. It is the right choice for larger loads, for varying demand, and wherever the process depends on consistent pressure. Most industrial steam applications end up pilot-operated.
How do I size a pressure reducing valve?
By flow and pressure, never by the size of the pipe it is going into. Sizing needs the required steam flow, the inlet pressure and its variation, and the required outlet pressure. The valve is then selected on capacity at that pressure drop.
Fitting a valve to match line size is the most common error we see, and it almost always produces an oversized valve. An oversized reducing valve operates barely off its seat, hunts, wears the seat quickly and gives poor pressure control at low load — the opposite of what was intended.
Do I need a safety valve downstream of a pressure reducing valve?
Yes, in almost every case. If the reducing valve fails open, full upstream pressure passes straight into downstream equipment that is not rated for it. A correctly sized safety valve downstream is what stops that becoming a burst heat exchanger or a failed jacket.
The downstream safety valve must be sized to pass the full capacity the reducing valve can deliver in the fully open position at maximum inlet pressure — not the normal process flow. Under-sizing it on normal duty flow is a common and dangerous mistake.
How should a pressure reducing valve be installed?
Follow the manufacturer’s orientation — most steam reducing valves are designed for horizontal pipework with the valve upright, and fitting one the wrong way round or in the wrong plane will stop it controlling properly.
Allow the specified straight pipe lengths upstream and downstream, take the control or sensing line from a straight run well clear of the valve outlet rather than immediately after it, size the downstream pipework for the increased steam volume after reduction, and make sure the line is properly drained and trapped. Most control complaints on new installations trace back to one of these rather than the valve itself.
How often should a pressure reducing valve be serviced?
There is no statutory interval as there is for safety valves, so servicing is driven by duty and condition. Annual inspection is a reasonable baseline for a steam station, and many plants align it with the boiler’s statutory examination so everything comes down together.
The practical indicators that a valve needs attention are outlet pressure drifting from setpoint, hunting that was not there before, audible noise increasing, or the valve failing to shut off at no load. Clean strainers and a working separator trap do more for valve life than any service interval.
Can a pressure reducing valve control temperature or flow instead?
Not directly — a reducing valve controls pressure. But in steam systems pressure and temperature are directly related at saturation, so controlling steam pressure does control the temperature at which it condenses, which is how most steam heating processes are regulated.
Where you need to control a process temperature rather than steam pressure, the correct device is a temperature control valve or a control valve with a temperature controller. We supply both, along with self-acting temperature regulators where no power supply is available. Tell us what you are actually controlling and we will specify against that rather than against the fitting that happens to be there now.