HOME > PRODUCTS

OUR PRODUCT

Steam Flowmeter

Steam is arguably the most difficult fluid to measure. Other than having to deal with its high temperatures and pressures, it also tends to come in two phases (water and steam) which most flowmeters can’t handle.

The ideal steam flowmeter is a vortex type flowmeter. It uses a highly reactive piezoelectric sensor which measures the frequency of vortices. There are no moving parts, making it highly durable. Our flowmeter is able to take high temperatures of up to 350ºC, making it suitable for measurement of both saturated and superheated steam. In addition, accuracies of up to ±1.5% can be achieved.

Model

Application

Max Min Temperature (°C)

Material

Connection

Size

Pressure

Medium

Max Capacity kg/h

Body and Cover Material

Secondary Pressure Range

Type of Trap

Glass O.D / Length

Pipe Size

PRODUCT ENQUIRY

TekFlow Vortex Flowmeter

Steam Flowmeter

    Description

    Once installed, the flowmeters are virtually zero maintenance and fuss free as no calibration is needed.

    TekFlow’s steam flowmeter is able to measure:
    – Volumetric Flow
    – Temperature
    – Mass Flow
    – Pressure 

    Our flowmeters are calibrated against a gas flow primary standard and traceable to USA National Institute of Standards and Technology (NIST).

    The flowmeter can be integrated into other systems such as a recorder to analyse data and help the user optimise steam flow. 

    Technical Specifications

    Accuracy: ±1.5% gases and steam
    Construction material: AISI 316 or AISI 304 stainless steel (Transmitter: Epoxy coated alumunium)
    Connections: Available in-line or wafer type 25 – 300mm (1” – 12”), insertion type 250 – 2000mm (10” – 80”)
    Pressure: Up to 420 barg
    Temperature: Up to 350ºC
    Turndown ratio: Between 10 : 1 to 40 : 1, depending on media
    Power Supply: 12 – 24V dc
    Intrinsically safe certified to Ex ib IIC T4, Flameproof to Ex d IIB T4
    Outputs: scaled pulse, 4 – 20mA, RS 485, HART protocol options
    Multivariable display: 7 digit LCD for instantaneous display, 8 digit for accumulated totals, Totalised gas mass flow, totalised standard or normal volumetric flow, standard or normal volumetric or mass flow rate, temperature, pressure